Control the MMX-8X8CAT-150M and MMX-4X4CAT-150M from Q-SYS

MMX-8X8CAT-150M MMX-8X8CAT-150M 8×8 HDBaseT Matrix Switcher with 8 PoC Receivers – 4K60 to 120m (394ft), 1080p to… 18Gbps HDMI 2.0b 8×8 Matrix with Mirrored HDMI + HDBaseT Outputs, Audio De-embedding & Web GUI Product page →

The MMX-8X8CAT-150M and MMX-4X4CAT-150M HDMI matrices each have a Q-SYS plugin to download, so a Q-SYS Core can route sources, recall presets and power the displays over the network. This guide is for integrators adding one to a Q-SYS design.

Applies to: MMX-8X8CAT-150M and MMX-4X4CAT-150M.

Where do I download the plugin?

Under Resources on the product page, or on the Q-SYS page at kanexpro.com/control-systems/qsys. Each model has its own plugin zip and its own Q-SYS plugin guide (PDF) with every control listed.

What do I need before I start?

  • Q-SYS Designer on a Windows computer, and a Q-SYS Core.
  • The matrix on the same network as the Core, or routed to it, with TCP port 8000 open between them.
  • A fixed IP address for the matrix (or a DHCP reservation). Its address is shown on the front panel and its web page.

How do I install it?

  1. Unzip the download.
  2. Copy the .qplug file into Documents\QSC\Q-Sys Designer\Plugins on the Q-SYS Designer computer, or drag it onto Designer's window.
  3. Restart Q-SYS Designer. The plugin appears in Schematic Elements under Plugins > KanexPro.
  4. Drag it into the design and set its properties: IP Address (the matrix), Port 8000 (change it only if the matrix's web page was set to another port) and Poll Interval (seconds between read-backs, default 10).
  5. Save the design to the Core and run it. The plugin connects by itself and shows its state on its Status control.

Use one plugin per matrix: for two units, add the plugin twice and give each its own IP address.

What can it control?

  • Source for each output, and one input to all outputs at once.
  • HDMI picture and HDBaseT picture on or off for each output.
  • Screen on or off for each output's display, over HDMI CEC.
  • Power (on or standby), Presets 1 to 8 and Save to a preset.
  • Remote commands to each source, such as power, play and pause.

It reads back each input's signal and EDID, each output's connection, the unit's power and whether the front panel is locked, so changes made on the front panel, remote or web page show in Q-SYS. Network, login and firmware settings stay on the matrix's own web page.

Can Q-SYS also send RS-232 commands to the displays?

Yes. The matrix passes serial commands out of each HDBaseT receiver's RS-232 port; see CAT Matrix Receivers: RS-232 Pass-Through and CEC for the wiring and the commands.

The plugin shows it is not connected. What should I check?

Check that the IP address in the plugin matches the matrix, that the Core can reach it on TCP port 8000, and that the Port property is 8000 unless the matrix's web page was changed. The Status control says why it is not connected.